Machine number: 1317-657
Basic functions:
4 zones (3 preheating zones, peak 1-stage with underside heating)
Condensate trap in the bottom cooling zone
Control system type C-Dias
Technical data:
Process chamber:
- Length: 3304 mm
- Preheating zones: 3
- Peak zone (top / bottom): 2 heating modules / double peak (1 / 1)
- Bottom heating preheating zone (option): 2
- Heated process length, total: 2081 mm
- Active convection section: 1533 mm
- Cooling zone length: 1223 mm
- Temperature detection: NiCr-Ni sensor in the gas flow
- Heating time: approx. 30 min
- Heat-up time with power limitation: approx. 60 min
- Heat transfer: 100 % forced convection
- Process temp. (preheating zone / peak zone): max. 300 °C / 350 °C (peak)
Transport chain:
- Usable working width with LP support: 60 - 460 mm
- Usable working height LP support: Cam level / PIN level ... - 10 mm
- Free passage height (top / bottom): 30 / 30 mm
- Max. load: 3 kg/m
Transport speed: 0.2 - 3 m/min
Average working speed: 0.33 - 0.53 m/min
Control unit: CDIAS with RT 7
Power supply:
- Supply voltage: 3-N, PE 230 / 400 V, 50 Hz
- Max. current consumption per phase: 60 A
- max. current consumption per phase with power limitation: 50 A
- Connected load: 41 kW
- Energy consumption in steady state: approx. 7 kW/h